Amazon Marketplace v2 connection
Introduction
An Amazon Marketplace connection, created using the Amazon Marketplace v2 connector, establishes access to Amazon Marketplace. These activities, once configured, interact with Amazon Marketplace through the connection.
Create or edit an Amazon Marketplace connection
A new Amazon Marketplace v2 connection is created using the Amazon Marketplace v2 connector from one of these locations:
- The design component palette's Project endpoints and connectors tab (see Design component palette).
- The Global Connections page (see Create a global endpoint in Global Connections).
An existing Amazon Marketplace v2 connection can be edited from these locations:
- The design component palette's Project endpoints and connectors tab (see Design component palette).
- The project pane's Components tab (see Component actions menu in Project pane Components tab).
- The Global Connections page (see Edit a global endpoint in Global Connections).
Configure an Amazon Marketplace connection
Each user interface element of the Amazon Marketplace v2 connection configuration screen is described below.
Tip
Fields with a variable icon support using global variables, project variables, and Jitterbit variables. Begin either by typing an open square bracket [
into the field or by clicking the variable icon to display a list of the existing variables to choose from.
-
Connection Name: Enter a name to use to identify the connection. The name must be unique for each Amazon Marketplace v2 connection and must not contain forward slashes (
/
) or colons (:
). This name is also used to identify the Amazon Marketplace v2 endpoint, which refers to both a specific connection and its activities. -
Schema: Select the schema, one of:
-
Marketplace
-
MWS Auth Token: Enter the MWS auth token.
-
Seller Id: Enter the seller ID.
-
-
SellingPartner
-
-
Marketplace: Select the marketplace, one of:
-
United States
-
Canada
-
Mexico
-
Brazil
-
Spain
-
United Kingdom
-
France
-
Belgium
-
Netherlands
-
Germany
-
Italy
-
Sweden
-
Poland
-
Egypt
-
Turkey
-
Saudi Arabia
-
United Arab Emirates
-
India
-
China
-
Singapore
-
Japan
-
Australia
-
-
Initiate OAuth: Select the OAuth setting, one of:
-
OFF
- OAuth Access Token: Enter the OAuth access token.
-
GETANDREFRESH
-
REFRESH
- OAuth Access Token: Enter the OAuth access token.
-
-
OAuth Client Id: Enter the OAuth client ID.
-
OAuth Client Secret: Enter the OAuth client secret.
-
OAuth Refresh Token: Enter the OAuth refresh token.
-
Include Reports: When selected, specifies to include reports.
-
Use Proxy Settings: Select to use private agent proxy settings.
-
Advanced Configurations: When selected, shows the Advanced Configurations Properties table, which is used to add additional configuration properties as key-value pairs.
Click the add icon to add a row to the table below and enter a key-value pair for each property.
To save the row, click the submit icon in the rightmost column.
To edit or delete a single row, hover over the rightmost column and use the edit icon or delete icon .
To delete all rows, click Clear All.
Important
Fields in the Advanced Configurations table display the variable icon only in edit mode. For these fields' variable values to be populated at runtime, the agent version must be at least 10.75 / 11.13.
-
Test: Click to verify the connection using the specified configuration. When the connection is tested, the latest version of the connector is downloaded by the agent(s) in the agent group associated with the current environment. This connector supports suspending the download of the latest connector version by using the Disable Auto Connector Update organization policy.
-
Save Changes: Click to save and close the connection configuration.
-
Discard Changes: After making changes to a new or existing configuration, click to close the configuration without saving. A message asks you to confirm that you want to discard changes.
-
Delete: After opening an existing connection configuration, click to permanently delete the connection from the project and close the configuration (see Component dependencies, deletion, and removal). A message asks you to confirm that you want to delete the connection.
Configure OAuth connections
This connector supports a connection using OAuth by using specific configuration properties. After selecting an auth scheme that includes Initiate OAuth, you will be able to specify the configuration in the fields that are displayed.
Note
Additional IDs, secrets, scopes, and other authentication tokens may be required in order to successfully complete the OAuth authentication. Check the endpoint documentation for additional information on their requirements.
For this connector, two scenarios are supported. In either scenario, you will need to use a third-party tool (such as Postman or a similar tool) to obtain the required access token or tokens from the endpoint involved. Both of these scenarios work only for single-agent groups. These are agent groups that consist of a single agent.
-
Scenario 1: Using an OAuth access token that expires after a set period of time.
With this configuration, you supply an OAuth access token that lasts for a set period of time, as determined by the particular endpoint. The connector will use the token to make the connection. The connection, however, will no longer work once the access token expires. You would configure the connector to use the token by setting these properties:
Configuration Property Value Initiate OAuth OFF
OAuth Access Token Set to the value of the OAuth access token obtained from the endpoint -
Scenario 2: Using an OAuth access token combined with an OAuth refresh token to enable automatic refresh of access.
With this configuration, the connector will use a refresh token to obtain a new access token once the current access token has expired. This is generally the best method of configuring OAuth.
You supply an OAuth access token and an OAuth refresh token, as determined by the particular endpoint. You would configure the connector to use these tokens by setting these properties:
Configuration Property Value Initiate OAuth REFRESH
OAuth Access Token Set to the value of the OAuth access token obtained from the endpoint OAuth Refresh Token Set to the value of the OAuth refresh token obtained from the endpoint
Note
If using multiple OAuth-based Amazon Marketplace v2 connections on the same private agent, set the configuration property OAuthSettingsLocation
to a unique writeable agent path for each connection. In the jitterbit.conf
file for the agent, set EnableLocalFileLocation=true
. If you don't perform these two steps, the multiple connections will use the same default path and overwrite each other.
Next steps
After an Amazon Marketplace connector connection has been created, you place an activity type on the design canvas to create activity instances to be used either as sources (to provide data in an operation) or as targets (to consume data in an operation).
Menu actions for a connection and its activity types are accessible from the project pane and design component palette. For details, see Actions menus in Connector basics.
These activity types are available:
-
Query: Retrieves records from a table at Amazon Marketplace and is intended to be used as a source in an operation.
-
Create: Inserts a record into a table at Amazon Marketplace and is intended to be used as a target in an operation.
-
Update: Updates a record in a table at Amazon Marketplace and is intended to be used as a target in an operation.
-
Delete: Deletes a record from a table at Amazon Marketplace and is intended to be used as a target in an operation.
-
Execute: Executes a procedure at Amazon Marketplace and is intended to be used as a target in an operation.